Subsequently, the AGS cells were morphologically examined using a

Subsequently, the AGS cells were morphologically examined using a fluorescent

microscope (Olympus IX81, Olympus, Japan) under a 40x objective. RNA isolation, quality control and cDNA synthesis Total RNA was isolated using RNeasy Mini SHP099 datasheet (Qiagen GmBH, Germany) according to the manufacturer’s protocol. RNA concentration and quality were determined using a NanoDrop ND-1000 spectrophotometer (NanoDrop Technologies, USA) and Agilent 2100 Bioanalyzer (Agilent Technologies, USA). For real-time PCR, cDNA was prepared using a First-Strand cDNA Synthesis Kit (GE Healthcare, USA), according to standard protocol. The Illumina TotalPrep RNA amplification Kit (Ambion Inc., USA) was used to amplify RNA for hybridization on Illumina BeadChips. https://www.selleckchem.com/products/Cyt387.html To synthesize first strand cDNA by reverse transcription, we used total RNA from each sample collected above. Following the Fedratinib mouse second strand cDNA synthesis and cDNA purification steps, the in vitro transcription to synthesize cRNA was prepared overnight for 12 h. Real-time PCR analysis Each sample was tested in triplicate by real-time quantitative PCR (rt-PCR) on the 7900HT

Fast Real-Time PCR system (Applied Biosystems). Expression of IL-8 was analyzed using custom IL-8 primer and probe (part no: 4331348, assay ID: Hs00174103_m1, Applied Biosystems). Mean cycle time (Ct) was calculated, and the comparative Ct-method [84] was utilized to control for background gene expression using reference gene GADPH (part no: 4333764F, Applied Biosystems). ELISA IL-8 protein was measured in the cell culture supernatant by the Quantikine Human CXCL8/IL-8 enzyme linked immunosorbent assay (ELISA) kit, according to manufacturer’s instructions (R&D Systems, USA). The test samples were not diluted. Serial dilutions of recombinant human IL-8 were used for

standard curves. The optical density of the wells was determined using a microtitre plate reader (Varioskan, Thermo Scientific, USA) set to a wavelength of 450 nm, with wavelength correction set to 540 nm cDNA oligonucleotide microarray analysis The gene expression profiles were measured using Illumina Human HT-12 v3 Expression BeadChip (Illumina, USA), which enables genome-wide expression analysis (48 800 transcripts, corresponding to approximately 37 800 genes) of 12 samples in parallel on a single microarray. 35967 of the probes were designed GPX6 using the RefSeq (build 36.2, release 22) library and 12.837 probes were derived from the UniGene (build 199) database [85, 86]. Bioinformatics and statistics R/BioConductor [87, 88], with the package Beadarray [82], were used for preprocessing of the microarray text data from BeadStudio. Spatial artifacts were removed using BASH [89] before the expression data were log2-transformed and quantile normalized. Moderated t-tests [90] were then performed for each probe on the array to test whether the differential expression between the starting point and the later time points was significant.

Comments are closed.